SWITCH SUN DELL EMC ED-DCX-8510-8B COM 256 PORTAS 16GB SEMINOVO

Estoque: 0 Marca: DELL Referência: 5998


Não disponível

** LEIA COM ATENÇÃO**
**EMITIMOS NF PARA PF E PJ**
**IMPOSTOS INCLUSOS PARA SP, FORA DE SP CONSULTAR IMPOSTOS PARA O SEU ESTADO**


SWITCH SUN DELL EMC ED-DCX-8510-8B 256 PORTAS 16GB SEMINOVO

ITENS INCLUSOS: CABO DE ENERGIA ELÉTRICA.

02 PLACAS DE COMANDO CP8
08 PLACAS FC16-32
02 PLACAS CR16-8
04 FONTES DE ALIMENTAÇÃO

TEMOS GBICS, NOS CONSULTE SOBRE A DISPONIBILIDADE E CUSTOS

NÃO POSSUI O KIT DE FIXAÇÃO EM RACK.

Emitimos Nota fiscal eletrônica deste produto.
Produto Seminovo, testado e revisado, em perfeito estado de funcionamento.
Garantia de 90 dias.
Imagens originais do produto no anuncio.

DCX_BF:FID128:admin> switchshow
switchName: DCX_BF
switchType: 120.0
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 191
switchId: fffcbf
switchWwn: 10:00:00:27:f8:7c:b5:00
zoning: ON (SAN_REPLICA_DISCO_BANCO_DC2_CT_IMPAR)
switchBeacon: OFF
FC Router: OFF
Fabric Name: Fabric_BF_25
HIF Mode: ON
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Ficon Switch: No, Address Mode 0]

Index Slot Port Address Media Speed State Proto
============================================================
0 1 0 bf0000 -- N16 No_Module FC
1 1 1 bf0100 -- N16 No_Module FC
2 1 2 bf0200 -- N16 No_Module FC
3 1 3 bf0300 -- N16 No_Module FC
4 1 4 bf0400 -- N16 No_Module FC
5 1 5 bf0500 -- N16 No_Module FC
6 1 6 bf0600 -- N16 No_Module FC
7 1 7 bf0700 -- N16 No_Module FC
8 1 8 bf0800 -- N16 No_Module FC
9 1 9 bf0900 -- N16 No_Module FC
10 1 10 bf0a00 -- N16 No_Module FC
11 1 11 bf0b00 -- N16 No_Module FC
12 1 12 bf0c00 -- N16 No_Module FC
13 1 13 bf0d00 -- N16 No_Module FC
14 1 14 bf0e00 -- N16 No_Module FC
15 1 15 bf0f00 -- N16 No_Module FC
128 1 16 bf8000 -- 10G No_Module FC LS
129 1 17 bf8100 -- 10G No_Module FC LS
130 1 18 bf8200 -- N16 No_Module FC
131 1 19 bf8300 -- N16 No_Module FC
132 1 20 bf8400 -- N16 No_Module FC
133 1 21 bf8500 -- N16 No_Module FC
134 1 22 bf8600 -- N16 No_Module FC
135 1 23 bf8700 -- N16 No_Module FC
136 1 24 bf8800 -- N16 No_Module FC
137 1 25 bf8900 -- N16 No_Module FC
138 1 26 bf8a00 -- N16 No_Module FC
139 1 27 bf8b00 -- N16 No_Module FC
140 1 28 bf8c00 -- N16 No_Module FC
141 1 29 bf8d00 -- N16 No_Module FC
142 1 30 bf8e00 -- 10G No_Module FC LS
143 1 31 bf8f00 -- 10G No_Module FC LS
16 2 0 bf1000 -- N16 No_Module FC
17 2 1 bf1100 -- N16 No_Module FC
18 2 2 bf1200 -- N16 No_Module FC
19 2 3 bf1300 -- N16 No_Module FC
20 2 4 bf1400 -- N16 No_Module FC
21 2 5 bf1500 -- N16 No_Module FC
22 2 6 bf1600 -- N16 No_Module FC
23 2 7 bf1700 -- N16 No_Module FC
24 2 8 bf1800 -- N16 No_Module FC
25 2 9 bf1900 -- N16 No_Module FC
26 2 10 bf1a00 -- N16 No_Module FC
27 2 11 bf1b00 -- N16 No_Module FC
28 2 12 bf1c00 -- N16 No_Module FC
29 2 13 bf1d00 -- N16 No_Module FC
30 2 14 bf1e00 -- N16 No_Module FC
31 2 15 bf1f00 -- N16 No_Module FC
144 2 16 bf9000 -- 10G No_Module FC LS
145 2 17 bf9100 -- 10G No_Module FC LS
146 2 18 bf9200 -- N16 No_Module FC
147 2 19 bf9300 -- N16 No_Module FC
148 2 20 bf9400 -- N16 No_Module FC
149 2 21 bf9500 -- N16 No_Module FC
150 2 22 bf9600 -- N16 No_Module FC
151 2 23 bf9700 -- N16 No_Module FC
152 2 24 bf9800 -- N16 No_Module FC
153 2 25 bf9900 -- N16 No_Module FC
154 2 26 bf9a00 -- N16 No_Module FC
155 2 27 bf9b00 -- N16 No_Module FC
156 2 28 bf9c00 -- N16 No_Module FC
157 2 29 bf9d00 -- N16 No_Module FC
158 2 30 bf9e00 -- 10G No_Module FC LS
159 2 31 bf9f00 -- 10G No_Module FC LS
32 3 0 bf2000 -- N16 No_Module FC
33 3 1 bf2100 -- N16 No_Module FC
34 3 2 bf2200 -- N16 No_Module FC
35 3 3 bf2300 -- N16 No_Module FC
36 3 4 bf2400 -- N16 No_Module FC
37 3 5 bf2500 -- N16 No_Module FC
38 3 6 bf2600 -- N16 No_Module FC
39 3 7 bf2700 -- N16 No_Module FC
40 3 8 bf2800 -- N16 No_Module FC
41 3 9 bf2900 -- N16 No_Module FC
42 3 10 bf2a00 -- N16 No_Module FC
43 3 11 bf2b00 -- N16 No_Module FC
44 3 12 bf2c00 -- N16 No_Module FC
45 3 13 bf2d00 -- N16 No_Module FC
46 3 14 bf2e00 -- N16 No_Module FC
47 3 15 bf2f00 -- N16 No_Module FC
160 3 16 bfa000 -- 10G No_Module FC LS
161 3 17 bfa100 -- 10G No_Module FC LS
162 3 18 bfa200 -- N16 No_Module FC
163 3 19 bfa300 -- N16 No_Module FC
164 3 20 bfa400 -- N16 No_Module FC
165 3 21 bfa500 -- N16 No_Module FC
166 3 22 bfa600 -- N16 No_Module FC
167 3 23 bfa700 -- N16 No_Module FC
168 3 24 bfa800 -- N16 No_Module FC
169 3 25 bfa900 -- N16 No_Module FC
170 3 26 bfaa00 -- N16 No_Module FC
171 3 27 bfab00 -- N16 No_Module FC
172 3 28 bfac00 -- N16 No_Module FC
173 3 29 bfad00 -- N16 No_Module FC
174 3 30 bfae00 -- 10G No_Module FC LS
175 3 31 bfaf00 -- 10G No_Module FC LS
48 4 0 bf3000 -- N16 No_Module FC
49 4 1 bf3100 -- N16 No_Module FC
50 4 2 bf3200 -- N16 No_Module FC
51 4 3 bf3300 -- N16 No_Module FC
52 4 4 bf3400 -- N16 No_Module FC
53 4 5 bf3500 -- N16 No_Module FC
54 4 6 bf3600 -- N16 No_Module FC
55 4 7 bf3700 -- N16 No_Module FC
56 4 8 bf3800 -- N16 No_Module FC
57 4 9 bf3900 -- N16 No_Module FC
58 4 10 bf3a00 -- N16 No_Module FC
59 4 11 bf3b00 -- N16 No_Module FC
60 4 12 bf3c00 -- N16 No_Module FC
61 4 13 bf3d00 -- N16 No_Module FC
62 4 14 bf3e00 -- N16 No_Module FC
63 4 15 bf3f00 -- N16 No_Module FC
176 4 16 bfb000 -- 10G No_Module FC LS
177 4 17 bfb100 -- N16 No_Module FC
178 4 18 bfb200 -- N16 No_Module FC
179 4 19 bfb300 -- N16 No_Module FC
180 4 20 bfb400 -- N16 No_Module FC
181 4 21 bfb500 -- N16 No_Module FC
182 4 22 bfb600 -- N16 No_Module FC
183 4 23 bfb700 -- N16 No_Module FC
184 4 24 bfb800 -- N16 No_Module FC
185 4 25 bfb900 -- N16 No_Module FC
186 4 26 bfba00 -- N16 No_Module FC
187 4 27 bfbb00 -- N16 No_Module FC
188 4 28 bfbc00 -- N16 No_Module FC
189 4 29 bfbd00 -- N16 No_Module FC
190 4 30 bfbe00 -- N16 No_Module FC
191 4 31 bfbf00 -- 10G No_Module FC LS
384 5 0 ------ -- 16G No_Module FC
385 5 1 ------ -- 16G No_Module FC
386 5 2 ------ -- 16G No_Module FC
387 5 3 ------ -- 16G No_Module FC
388 5 4 ------ -- 16G No_Module FC
389 5 5 ------ -- 16G No_Module FC
390 5 6 ------ -- 16G No_Module FC
391 5 7 ------ -- 16G No_Module FC
392 5 8 ------ -- 16G No_Module FC
393 5 9 ------ -- 16G No_Module FC
394 5 10 ------ -- 16G No_Module FC
395 5 11 ------ -- 16G No_Module FC
396 5 12 ------ -- 16G No_Module FC
397 5 13 ------ -- 16G No_Module FC
398 5 14 ------ -- 16G No_Module FC
399 5 15 ------ -- 16G No_Module FC
400 5 16 ------ -- 16G No_Module FC
401 5 17 ------ -- 16G No_Module FC
402 5 18 ------ -- 16G No_Module FC
403 5 19 ------ -- 16G No_Module FC
404 5 20 ------ -- 16G No_Module FC
405 5 21 ------ -- 16G No_Module FC
406 5 22 ------ -- 16G No_Module FC
407 5 23 ------ -- 16G No_Module FC
408 5 24 ------ -- 16G No_Module FC
409 5 25 ------ -- 16G No_Module FC
410 5 26 ------ -- 16G No_Module FC
411 5 27 ------ -- 16G No_Module FC
412 5 28 ------ -- 16G No_Module FC
413 5 29 ------ -- 16G No_Module FC
414 5 30 ------ -- 16G No_Module FC
415 5 31 ------ -- 16G No_Module FC
1152 5 32 ------ -- 16G No_Module FC
1153 5 33 ------ -- 16G No_Module FC
1154 5 34 ------ -- 16G No_Module FC
1155 5 35 ------ -- 16G No_Module FC
1156 5 36 ------ -- 16G No_Module FC
1157 5 37 ------ -- 16G No_Module FC
1158 5 38 ------ -- 16G No_Module FC
1159 5 39 ------ -- 16G No_Module FC
1160 5 40 ------ -- 16G No_Module FC
1161 5 41 ------ -- 16G No_Module FC
1162 5 42 ------ -- 16G No_Module FC
1163 5 43 ------ -- 16G No_Module FC
1164 5 44 ------ -- 16G No_Module FC
1165 5 45 ------ -- 16G No_Module FC
1166 5 46 ------ -- 16G No_Module FC
1167 5 47 ------ -- 16G No_Module FC
1168 5 48 ------ -- 16G No_Module FC
1169 5 49 ------ -- 16G No_Module FC
1170 5 50 ------ -- 16G No_Module FC
1171 5 51 ------ -- 16G No_Module FC
1172 5 52 ------ -- 16G No_Module FC
1173 5 53 ------ -- 16G No_Module FC
1174 5 54 ------ -- 16G No_Module FC
1175 5 55 ------ -- 16G No_Module FC
1176 5 56 ------ -- 16G No_Module FC
1177 5 57 ------ -- 16G No_Module FC
1178 5 58 ------ -- 16G No_Module FC
1179 5 59 ------ -- 16G No_Module FC
1180 5 60 ------ -- 16G No_Module FC
1181 5 61 ------ -- 16G No_Module FC
1182 5 62 ------ -- 16G No_Module FC
1183 5 63 ------ -- 16G No_Module FC
416 8 0 ------ -- 16G No_Module FC
417 8 1 ------ -- 16G No_Module FC
418 8 2 ------ -- 16G No_Module FC
419 8 3 ------ -- 16G No_Module FC
420 8 4 ------ -- 16G No_Module FC
421 8 5 ------ -- 16G No_Module FC
422 8 6 ------ -- 16G No_Module FC
423 8 7 ------ -- 16G No_Module FC
424 8 8 ------ -- 16G No_Module FC
425 8 9 ------ -- 16G No_Module FC
426 8 10 ------ -- 16G No_Module FC
427 8 11 ------ -- 16G No_Module FC
428 8 12 ------ -- 16G No_Module FC
429 8 13 ------ -- 16G No_Module FC
430 8 14 ------ -- 16G No_Module FC
431 8 15 ------ -- 16G No_Module FC
432 8 16 ------ -- 16G No_Module FC
433 8 17 ------ -- 16G No_Module FC
434 8 18 ------ -- 16G No_Module FC
435 8 19 ------ -- 16G No_Module FC
436 8 20 ------ -- 16G No_Module FC
437 8 21 ------ -- 16G No_Module FC
438 8 22 ------ -- 16G No_Module FC
439 8 23 ------ -- 16G No_Module FC
440 8 24 ------ -- 16G No_Module FC
441 8 25 ------ -- 16G No_Module FC
442 8 26 ------ -- 16G No_Module FC
443 8 27 ------ -- 16G No_Module FC
444 8 28 ------ -- 16G No_Module FC
445 8 29 ------ -- 16G No_Module FC
446 8 30 ------ -- 16G No_Module FC
447 8 31 ------ -- 16G No_Module FC
1184 8 32 ------ -- 16G No_Module FC
1185 8 33 ------ -- 16G No_Module FC
1186 8 34 ------ -- 16G No_Module FC
1187 8 35 ------ -- 16G No_Module FC
1188 8 36 ------ -- 16G No_Module FC
1189 8 37 ------ -- 16G No_Module FC
1190 8 38 ------ -- 16G No_Module FC
1191 8 39 ------ -- 16G No_Module FC
1192 8 40 ------ -- 16G No_Module FC
1193 8 41 ------ -- 16G No_Module FC
1194 8 42 ------ -- 16G No_Module FC
1195 8 43 ------ -- 16G No_Module FC
1196 8 44 ------ -- 16G No_Module FC
1197 8 45 ------ -- 16G No_Module FC
1198 8 46 ------ -- 16G No_Module FC
1199 8 47 ------ -- 16G No_Module FC
1200 8 48 ------ -- 16G No_Module FC
1201 8 49 ------ -- 16G No_Module FC
1202 8 50 ------ -- 16G No_Module FC
1203 8 51 ------ -- 16G No_Module FC
1204 8 52 ------ -- 16G No_Module FC
1205 8 53 ------ -- 16G No_Module FC
1206 8 54 ------ -- 16G No_Module FC
1207 8 55 ------ -- 16G No_Module FC
1208 8 56 ------ -- 16G No_Module FC
1209 8 57 ------ -- 16G No_Module FC
1210 8 58 ------ -- 16G No_Module FC
1211 8 59 ------ -- 16G No_Module FC
1212 8 60 ------ -- 16G No_Module FC
1213 8 61 ------ -- 16G No_Module FC
1214 8 62 ------ -- 16G No_Module FC
1215 8 63 ------ -- 16G No_Module FC
64 9 0 bf4000 -- N16 No_Module FC
65 9 1 bf4100 -- N16 No_Module FC
66 9 2 bf4200 -- N16 No_Module FC
67 9 3 bf4300 -- N16 No_Module FC
68 9 4 bf4400 -- N16 No_Module FC
69 9 5 bf4500 -- N16 No_Module FC
70 9 6 bf4600 -- N16 No_Module FC
71 9 7 bf4700 -- N16 No_Module FC
72 9 8 bf4800 -- N16 No_Module FC
73 9 9 bf4900 -- N16 No_Module FC
74 9 10 bf4a00 -- N16 No_Module FC
75 9 11 bf4b00 -- N16 No_Module FC
76 9 12 bf4c00 -- N16 No_Module FC
77 9 13 bf4d00 -- N16 No_Module FC
78 9 14 bf4e00 -- N16 No_Module FC
79 9 15 bf4f00 -- N16 No_Module FC
192 9 16 bfc000 -- N16 No_Module FC
193 9 17 bfc100 -- N16 No_Module FC
194 9 18 bfc200 -- N16 No_Module FC
195 9 19 bfc300 -- N16 No_Module FC
196 9 20 bfc400 -- N16 No_Module FC
197 9 21 bfc500 -- N16 No_Module FC
198 9 22 bfc600 -- N16 No_Module FC
199 9 23 bfc700 -- N16 No_Module FC
200 9 24 bfc800 -- N16 No_Module FC
201 9 25 bfc900 -- N16 No_Module FC
202 9 26 bfca00 -- N16 No_Module FC
203 9 27 bfcb00 -- N16 No_Module FC
204 9 28 bfcc00 -- N16 No_Module FC
205 9 29 bfcd00 -- N16 No_Module FC
206 9 30 bfce00 -- N16 No_Module FC
207 9 31 bfcf00 -- N16 No_Module FC
80 10 0 bf5000 -- N16 No_Module FC
81 10 1 bf5100 -- N16 No_Module FC
82 10 2 bf5200 -- N16 No_Module FC
83 10 3 bf5300 -- N16 No_Module FC
84 10 4 bf5400 -- N16 No_Module FC
85 10 5 bf5500 -- N16 No_Module FC
86 10 6 bf5600 -- N16 No_Module FC
87 10 7 bf5700 -- N16 No_Module FC
88 10 8 bf5800 -- N16 No_Module FC
89 10 9 bf5900 -- N16 No_Module FC
90 10 10 bf5a00 -- N16 No_Module FC
91 10 11 bf5b00 -- N16 No_Module FC
92 10 12 bf5c00 -- N16 No_Module FC
93 10 13 bf5d00 -- N16 No_Module FC
94 10 14 bf5e00 -- N16 No_Module FC
95 10 15 bf5f00 -- N16 No_Module FC
208 10 16 bfd000 -- N16 No_Module FC
209 10 17 bfd100 -- N16 No_Module FC
210 10 18 bfd200 -- N16 No_Module FC
211 10 19 bfd300 -- N16 No_Module FC
212 10 20 bfd400 -- N16 No_Module FC
213 10 21 bfd500 -- N16 No_Module FC
214 10 22 bfd600 -- N16 No_Module FC
215 10 23 bfd700 -- N16 No_Module FC
216 10 24 bfd800 -- N16 No_Module FC
217 10 25 bfd900 -- N16 No_Module FC
218 10 26 bfda00 -- N16 No_Module FC
219 10 27 bfdb00 -- N16 No_Module FC
220 10 28 bfdc00 -- N16 No_Module FC
221 10 29 bfdd00 -- N16 No_Module FC
222 10 30 bfde00 -- N16 No_Module FC
223 10 31 bfdf00 -- N16 No_Module FC
96 11 0 bf6000 -- N16 No_Module FC
97 11 1 bf6100 -- N16 No_Module FC
98 11 2 bf6200 -- N16 No_Module FC
99 11 3 bf6300 -- N16 No_Module FC
100 11 4 bf6400 -- N16 No_Module FC
101 11 5 bf6500 -- N16 No_Module FC
102 11 6 bf6600 -- N16 No_Module FC
103 11 7 bf6700 -- N16 No_Module FC
104 11 8 bf6800 -- N16 No_Module FC
105 11 9 bf6900 -- N16 No_Module FC
106 11 10 bf6a00 -- N16 No_Module FC
107 11 11 bf6b00 -- N16 No_Module FC
108 11 12 bf6c00 -- N16 No_Module FC
109 11 13 bf6d00 -- N16 No_Module FC
110 11 14 bf6e00 -- N16 No_Module FC
111 11 15 bf6f00 -- N16 No_Module FC
224 11 16 bfe000 -- N16 No_Module FC
225 11 17 bfe100 -- N16 No_Module FC
226 11 18 bfe200 -- N16 No_Module FC
227 11 19 bfe300 -- N16 No_Module FC
228 11 20 bfe400 -- N16 No_Module FC
229 11 21 bfe500 -- N16 No_Module FC
230 11 22 bfe600 -- N16 No_Module FC
231 11 23 bfe700 -- N16 No_Module FC
232 11 24 bfe800 -- N16 No_Module FC
233 11 25 bfe900 -- N16 No_Module FC
234 11 26 bfea00 -- N16 No_Module FC
235 11 27 bfeb00 -- N16 No_Module FC
236 11 28 bfec00 -- N16 No_Module FC
237 11 29 bfed00 -- N16 No_Module FC
238 11 30 bfee00 -- N16 No_Module FC
239 11 31 bfef00 -- N16 No_Module FC
112 12 0 bf7000 -- N16 No_Module FC
113 12 1 bf7100 -- N16 No_Module FC
114 12 2 bf7200 -- N16 No_Module FC
115 12 3 bf7300 -- N16 No_Module FC
116 12 4 bf7400 -- N16 No_Module FC
117 12 5 bf7500 -- N16 No_Module FC
118 12 6 bf7600 -- N16 No_Module FC
119 12 7 bf7700 -- N16 No_Module FC
120 12 8 bf7800 -- N16 No_Module FC
121 12 9 bf7900 -- N16 No_Module FC
122 12 10 bf7a00 -- N16 No_Module FC
123 12 11 bf7b00 -- N16 No_Module FC
124 12 12 bf7c00 -- N16 No_Module FC
125 12 13 bf7d00 -- N16 No_Module FC
126 12 14 bf7e00 -- N16 No_Module FC
127 12 15 bf7f00 -- N16 No_Module FC
240 12 16 bff000 -- N16 No_Module FC
241 12 17 bff100 -- N16 No_Module FC
242 12 18 bff200 -- N16 No_Module FC
243 12 19 bff300 -- N16 No_Module FC
244 12 20 bff400 -- N16 No_Module FC
245 12 21 bff500 -- N16 No_Module FC
246 12 22 bff600 -- N16 No_Module FC
247 12 23 bff700 -- N16 No_Module FC
248 12 24 bff800 -- N16 No_Module FC
249 12 25 bff900 -- N16 No_Module FC
250 12 26 bffa00 -- N16 No_Module FC
251 12 27 bffb00 -- N16 No_Module FC
252 12 28 bffc00 -- N16 No_Module FC
253 12 29 bffd00 -- N16 No_Module FC
254 12 30 bffe00 -- N16 No_Module FC Disabled (Persistent) (FMS Mode)
255 12 31 bfff00 -- N16 No_Module FC Disabled (Persistent) (FMS Mode)
DCX_BF:FID128:admin> licenseshow
gD4gLHg4PtTSCFJfSagWrW7QWSrHXa77BSEQG:
Extended Fabric license
Fabric Watch (Fabric Vision capable) license
Performance Monitor (Fabric Vision capable) license
Trunking license
Adaptive Networking - obsolete license
Server Application Optimization - obsolete license
NFRBKSHN7CMRB3KH7CKJgSfEAW7NSrHXBA7tL:
FICON_CUP license
SfMtmaR3YYXHWHfZDWAaLDTCCJECP7W4YQSPBJGACA7A:
10 Gigabit FCIP/Fibre Channel (FTR_10G) license
Capacity 4
Consumed 4
Configured Blade Slots 1,2,3,4
DCX_BF:FID128:admin> firmwareshow
Slot Name Appl Primary/Secondary Versions Status
--------------------------------------------------------------------------
7 CP1 FOS v8.2.0a ACTIVE *
v8.2.0a
DCX_BF:FID128:admin> version
Kernel: 2.6.14.2
Fabric OS: v8.2.0a
Made on: Tue Mar 6 15:49:22 2018
Flash: Sun Jan 26 00:37:16 2020
BootProm: 1.0.16
DCX_BF:FID128:admin> chassisshow

Chassis Family: DCX8510-8
Chassis Backplane Revision: 0

SW BLADE Slot: 1
Header Version: 2
Power Consume Factor: -140W
Power Usage: -72W
Factory Part Num: 60-0000143-13
Factory Serial Num: BQA0432H01R
Manufacture: Day: 16 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

SW BLADE Slot: 2
Header Version: 2
Power Consume Factor: -140W
Power Usage: -76W
Factory Part Num: 60-0000143-15
Factory Serial Num: BQA0403K043
Manufacture: Day: 22 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

SW BLADE Slot: 3
Header Version: 2
Power Consume Factor: -140W
Power Usage: -73W
Factory Part Num: 60-0000143-15
Factory Serial Num: BQA0417K012
Manufacture: Day: 23 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

SW BLADE Slot: 4
Header Version: 2
Power Consume Factor: -140W
Power Usage: -76W
Factory Part Num: 60-0000143-15
Factory Serial Num: BQA0417K08R
Manufacture: Day: 23 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

CP BLADE Slot: 6
Header Version: 2
Power Consume Factor: -40W
Factory Part Num: 60-1000376-10
Factory Serial Num: AHJ0416K019
Manufacture: Day: 18 Month: 4 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

CP BLADE Slot: 7
Header Version: 2
Power Consume Factor: -40W
Factory Part Num: 60-1000376-10
Factory Serial Num: AHJ0416K02W
Manufacture: Day: 18 Month: 4 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

CORE BLADE Slot: 5
Header Version: 2
Power Consume Factor: -240W
Power Usage: -170W
Factory Part Num: 60-1002054-12
Factory Serial Num: BPZ0414K033
Manufacture: Day: 2 Month: 4 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

CORE BLADE Slot: 8
Header Version: 2
Power Consume Factor: -240W
Power Usage: -162W
Factory Part Num: 60-1002054-12
Factory Serial Num: BPZ0414K02R
Manufacture: Day: 2 Month: 4 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

SW BLADE Slot: 9
Header Version: 2
Power Consume Factor: -140W
Power Usage: -76W
Factory Part Num: 60-0000143-15
Factory Serial Num: BQA0410K01E
Manufacture: Day: 23 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

SW BLADE Slot: 10
Header Version: 2
Power Consume Factor: -140W
Power Usage: -81W
Factory Part Num: 60-0000143-15
Factory Serial Num: BQA0417K019
Manufacture: Day: 22 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

SW BLADE Slot: 11
Header Version: 2
Power Consume Factor: -140W
Power Usage: -76W
Factory Part Num: 60-0000143-15
Factory Serial Num: BQA0410K030
Manufacture: Day: 23 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3493 days
Time Awake: 0 days

SW BLADE Slot: 12
Header Version: 2
Power Consume Factor: -140W
Power Usage: -83W
Factory Part Num: 60-0000143-15
Factory Serial Num: BQA0417K02J
Manufacture: Day: 23 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3493 days
Time Awake: 0 days

POWER SUPPLY Unit: 1
Header Version: 2
Power Consume Factor: 2000W
Factory Part Num: 23-0000067-01
Factory Serial Num: AGC2E05K00A
Manufacture: Day: 25 Month: 1 Year: -8697
Update: Day: 14 Month: 5 Year: 2024
Time Alive: 3483 days
Time Awake: 0 days

POWER SUPPLY Unit: 2
Header Version: 2
Power Consume Factor: 2000W
Factory Part Num: 23-0000067-01
Factory Serial Num: AGC2E05K0G1
Manufacture: Day: 5 Month: 2 Year: -8697
Update: Day: 6 Month: 5 Year: 2024
Time Alive: 3483 days
Time Awake: 0 days

POWER SUPPLY Unit: 3
Header Version: 2
Power Consume Factor: 2000W
Factory Part Num: 23-0000067-01
Factory Serial Num: AGC2E05K00C
Manufacture: Day: 25 Month: 1 Year: -8697
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3497 days
Time Awake: 0 days

POWER SUPPLY Unit: 4
Header Version: 2
Power Consume Factor: 2000W
Factory Part Num: 23-0000067-01
Factory Serial Num: AGC2E06K00Z
Manufacture: Day: 6 Month: 2 Year: -8697
Update: Day: 8 Month: 5 Year: 2024
Time Alive: 3497 days
Time Awake: 0 days

FAN Unit: 1
Header Version: 2
Power Consume Factor: -90W
Factory Part Num: 60-1000384-12
Factory Serial Num: AGB1921K03C
Manufacture: Day: 26 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

FAN Unit: 2
Header Version: 2
Power Consume Factor: -90W
Factory Part Num: 60-1000384-12
Factory Serial Num: AGB1921K039
Manufacture: Day: 26 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

FAN Unit: 3
Header Version: 2
Power Consume Factor: -90W
Factory Part Num: 60-1000384-12
Factory Serial Num: AGB1921K030
Manufacture: Day: 26 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

WWN Unit: 1
Header Version: 2
Power Consume Factor: -1W
Factory Part Num: 60-1000491-05
Factory Serial Num: AFX1921K01R
Manufacture: Day: 26 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days
ID: EMC0000CA
Part Num: CONTRX0000DCX
Serial Num: BRCAFX1921K01R

WWN Unit: 2
Header Version: 2
Power Consume Factor: -1W
Factory Part Num: 60-1000491-05
Factory Serial Num: AJX0417K03X
Manufacture: Day: 26 Month: 5 Year: 2014
Update: Day: 15 Month: 5 Year: 2024
Time Alive: 3498 days
Time Awake: 0 days

Chassis Factory Serial Num: AFY1921K00B


Visão geral
Conectividade SAN reforçada
Obtenha o desempenho de rede que você precisa para cargas de trabalho de última geração com a Backbone (rede de transmissão) Brocade DCX 8510, criada sob medida para funcionamento em rede contínuo e escalável para cloud computing privada.

Funcionamento em rede contínuo
Experimente a conectividade contínua projetada para fornecer comunicações de SAN completas eficientes e confiáveis.
Confirme o serviço de rede ininterrupto com o provisionamento de malha dinâmico.
Ajuda a eliminar a reconfiguração da malha ao adicionar ou substituir servidores.
Reduz a necessidade de modificação de zona e mascaramento de número de unidade lógica (LUN).
Permite que dispositivos sejam movidos dentro de um switch, como migrar World Wide Names (WWNs) virtuais com um simples comando move.
Ajuda a proteger a integridade no nível do vínculo de malha com validação de vínculo e unidades ópticas completas.
Identifica e isola problemas ópticos e de cabo com maior rapidez.
Verifica de forma não invasiva a integridade de transceptores e cabos através de testes ópticos e elétricos, verificações de integridade de cabos, diagnóstico digital e mais.
Ajuda a garantir o desempenho previsível de aplicativos sobre vínculos com medições granulares de distância e latência e simulações de perfil de E/S no nível do aplicativo.
Experience nonstop connectivity designed to provide efficient and reliable end-to-end SAN communications.Confirm uninterrupted network service with dynamic fabric provisioning.

? Helps eliminate fabric reconfiguration when adding or replacing servers.
? Reduces the need for zone modification and logical unit number (LUN) masking.
? Allows devices to be moved within a switch, such as migrating virtual World Wide Names (WWNs), with a simple move command.

Help safeguard fabric link-level integrity with end-to-end optics and link validation.

? Identify and isolate optics and cable problems faster.
? Non-intrusively verify transceiver and cable health through electrical and optical tests, cable health checks, digital diagnostics and more.

Help ensure predictable application performance over links with granular latency and distance measurements and application-level I/O profile simulations.
Conectividade confiável
Acompanhe a demanda dinâmica dos negócios com uma base sólida de escalabilidade e confiabilidade que permite implantações eficientes de cloud computing privada, bem como data centers virtualizados.

Aprimore o design escalável de rede de storage compartilhado para atender aos requisitos de storage de cloud computing, inclusive:
Uma topologia de rede plana que conecta um chassi a outro sem usar roteadores.
Conectividade entre todos os pontos, onde um nó pode enviar/receber tráfego para/de outro nó dentro da rede através de uma única interface.
Interconexão de baixa latência para uma rápida comunicação com o mínimo de atraso.
Otimiza a implantação e consolida a administração da SAN completa com ferramentas de gerenciamento de rede aprimoradas, como:
Novo diagnóstico de portas em sequência e monitoramento avançado que acelera a implantação e ajuda a melhorar a eficiência da solução de problemas.
Network Advisor, que ajuda a centralizar a conectividade do servidor e o gerenciamento de recursos.
Monitoramento de energia em toda a malha que oferece suporte a operações de baixo consumo de energia.
Escolha um dos dois modelos de Backbone (rede de transmissão) Brocade DCX 8510:
DCX 8510-4, com até 192 portas a 16 Gbps, para mecanismos de aplicativos ou núcleos de malhas de médias empresas e de extremidade de grandes empresas.
DCX 8510-8, com até 384 portas a 16 Gbps, para núcleos de malhas de grandes empresas

Desempenho excepcional
Adicione velocidade e confiabilidade de última geração à infraestrutura da sua SAN com a Backbone (rede de transmissão) Brocade DCX 8510, projetada para maximizar o desempenho de aplicativos e storage para aplicativos com uso intenso de largura de banda e de E/S.
A largura de banda do chassi total de até 8,2 Tbps fornece até o dobro da largura de banda das soluções concorrentes.
Oferece até 384 portas a 16 Gbps que fornecem desempenho aproximadamente 40% maior por porta do que as SANs de 10 GbE1.
A largura de banda de slot de 512 Gbps ajuda a minimizar o excesso de assinaturas, aprimorando o número de portas de taxa de linha disponíveis e permitindo melhores contratos de nível de serviço (SLAs).
A Backbone Brocade DCX 8510 fornece um desempenho excepcional para suportar o rápido crescimento do tráfego e dos requisitos para ambientes virtualizados. Ela também permite que você consolide, ajuste a escala e automatize seus recursos de TI, aproveitando os benefícios da virtualização para ajudar o seu negócio a evoluir para as arquiteturas de cloud computing privada.


Portas Fibre Channel
Chassi único: até 384 portas (Brocade DCX 8510-8) ou 192 portas (Brocade DCX 8510-4) Fibre Channel universais (E, F, D, M e EX) de 16 Gbps usando até oito blades Fibre Channel de 32 ou 48 portas. Até 512 portas (Brocade DCX 8510-8) ou 256 portas (Brocade DCX 8510-4) Fibre Channel universais (E, F, D, M e EX) de 8 Gbps usando blades Fibre Channel de 64 portas de 8 Gbps.
Vários chassis: até 2.304 portas (Brocade DCX 8510-8) ou 960 portas (Brocade DCX 8510-4) Fibre Channel universais de 16 Gbps; até 3.072 portas (Brocade DCX 8510-8) ou 1.280 portas (Brocade DCX 8510-4) Fibre Channel universais de 8 Gbps; portas ICL (32 ou 16 por chassi, QSFP óptico) conectam até seis chassis Brocade DCX 8510.

Desempenho
Fibre Channel Sensor automático de velocidade de porta de 2, 4, 8 e 16 Gbps
DCB/CEE: velocidade de linha de 2,125 Gbps, full duplex; velocidade de linha de 4,25 Gbps, full duplex; velocidade de linha de 8,5 Gbps, full duplex; velocidade de linha de 10,53 Gbps, full duplex; velocidade de linha de 14,025 Gbps, full duplex
Tamanho máximo do quadro: carga útil de 2.112 bytes

ISL Trunking
Tronco baseado em quadros com até oito portas de 16 Gbps por tronco ISL; até 128 Gbps por tronco ISL Balanceamento de carga baseado em troca entre ISLs com DPS incluído no sistema operacional de malha Brocade

Classes de serviço
Classe 2, Classe 3, Classe F (quadros entre switches)

Tipos de porta
D_Port (porta de diagnóstico), E_Port, EX_Port, F_Port, M_Port (porta de espelhamento); autodescoberta baseada no tipo de switch (U_Port); controle de tipo de porta opcional

Tipos de mídia
16 Gbps: os blades Brocade FC16-32 e -48 exigem Brocade com conexão automática SFP+, conector LC; SWL e LWL de 16 Gbps
8 Gbps: os blades Brocade FC16-32 e -48; Brocade FX8-24; e Brocade FS8-18 exigem Brocade com conexão automática SFP+, conector LC; SWL, LWL e ELWL de 8 Gbps
8 Gbps: os blades Brocade FC8-64 exigem mSFP com conexão automática Brocade, conector LC mSFP; apenas SWL de 8 Gbps
QSFP ICL: os blades Brocade CR16-8 e CR16-4 exigem QSFP de conexão automática Brocade, conector MTP; SWL de 4 × 16 Gbps
Nota: a distância do Fibre Channel está sujeita ao cabo de fibra óptica e à velocidade da porta

Serviços de malha
Monitoramento de desempenho avançado (APM) Brocade (inclui comunicadores de nível superior para E_Port, F_Port e modo de malha); rede adaptável Brocade (limite de taxa de entrada, isolamento de tráfego, QoS); detecção de gargalo; zoneamento avançado Brocade (zoneamento padrão, porta/zoneamento WWN, zoneamento de transmissão); provisionamento de malha dinâmico (DFP); seleção de caminho dinâmica (DPS); malhas estendidas Brocade; recuperação de crédito BB aprimorado; vigilância de malha Brocade; FDMI; redirecionamento de quadro; tronco baseado em quadro; FSPF; roteamento integrado; IPoFC; tronco ISL; servidor de gerenciamento; NPIV; NTP v3; vedação de portas; notificação de mudança de estado registrado (RSCN); serviço de comprometimento confiável (RCS); otimização de aplicativos de servidor (SAO) Brocade; servidor de nomes simples (SNS); malhas virtuais (switch lógico, malha lógica)

Gerenciamento
Software de gerenciamento
HTTP, SNMP v1/v3 (MIB FE, MIB de gerenciamento FC), SSH; auditoria, syslog; ferramentas da Web avançadas Brocade, Brocade APM, Brocade Fabric Watch; Brocade Network Advisor SAN Enterprise (Brocade DCX 8510-8, Brocade DCX 8510-4) ou Brocade Network Advisor SAN Professional/Professional Plus (apenas Brocade DCX 8510-4); Interface de linha de comando (CLI); compatível com SMI-S; Domínios administrativos; licenças de avaliação para recursos suplementares

Acesso ao gerenciamento
Ethernet 10/100/1000 (RJ-45) por processador de controle, em banda sobre Fibre Channel; porta serial (RJ-45) e um USB por módulo processador de controle; integração do recurso call-home ativado através de Brocade DCFM, EFCM e Brocade Network Advisor

Diagnóstico
Diagnóstico off-line D_Port, inclusive loopback elétrico/óptico, tráfego/latência/distância de vínculo; POST e diagnósticos on-line/off-line incorporados, inclusive monitoramento ambiental, FCping e Pathinfo (traceroute FC), visualizador de quadros, espelhamento de portas de reinicialização daemon sem interrupções (porta SPAN), monitoramento da integridade óptica, monitoramento de energia (apenas blades de 16 Gbps), registro RAStrace e detecção de reinicialização contínua (RRD)

Chassi
USB:
1 porta USB por processador de controle para download de firmware, segurança do suporte e upload/download da configuração
Mecânica
Enclosure
Fluxo de ar do painel posterior para a porta; o Brocade 8510-4 é fornecido com prateleira 1 U de saída

Tamanho
Brocade DCX 8510-8
Largura: 43,74 cm (17,22 polegadas)
Altura: 61,24 cm (24,11 polegadas, 14 U)
Profundidade (sem porta): 61,19 cm (24,09 polegadas)
Profundidade (com porta): 73,20 cm (28,82 polegadas)

Brocade DCX 8510-4
Largura: 43,74 cm (17,22 polegadas)
Altura: 35 cm (13,78 polegadas, 8 U) mais prateleira de saída de 4,37 cm (1,72 polegadas, 1 U)
Profundidade sem porta: 61,19 cm (24,09 polegadas)
Profundidade com porta: 73,20 cm (28,82 polegadas)

Peso do sistema
103,50 kg (228,20 polegadas) para configuração de 384 portas totalmente preenchidas
39,55 kg (82,20 lb) para chassi

68,04 kg (150 lb) para configuração de 192 portas totalmente preenchidas
25,76 kg (56,80 lb) para chassi

Aspectos ambientais
Temperatura
Operacional: 0° C a 40° C (32° F a 104° F)
Não operacional: ?25° C a 70° C (?13° F a 158° F)

Umidade
Operacional: UR de 20% a 85% sem condensação a 40° C (104° F)
Não operacional e storage (sem condensação): 10% a 93% a 70 °C (158 °F)

Altitude
Até 3.000 metros (9.842 pés)

Choque
Operacional: 20 g, 6 ms, meio seno
Não operacional: 33 g, 11 ms, meio seno

Vibração
Operacional: 0,5 g p-p, 5 a 500 Hz
Não operacional: 2,0 g p-p, 5 a 500 Hz

Emissões de CO2
7,8 toneladas métricas por ano (com 384 portas a 0,42 kg/kWh)
0,95 kg por Gbps por ano

4,3 toneladas métricas por ano (com 256 portas a 0,42 kg/kWh)
1,04 kg por Gbps por ano

Fluxo de ar
Máximo: 42 CFM
Nominal (velocidade de 65%): 35 CFM

Dissipação de calor
Mínima: configuração de 32 portas (sem QSFP), 873 W, 2.982 BTU/h
Máxima: configuração de 384 portas (totalmente carregado com QSFPs), 2.242 W, 7.654 BTU/h

Dissipação de calor
Mínima: configuração de 32 portas (sem QSFP), 618 W, 2.111 BTU/h
Máxima: configuração de 192 portas (totalmente carregado com QSFPs), 1.195 W, 4.078 BTU/h

Alimentação
Máximo
350 watts

Consumo
306 watts

Tensão de entrada
85 a 132 VCA; 1.000 W
180 a 264 VCA; 2.000 W

Frequência de linha de entrada
47 a 63 Hz

Corrente de pico
Máximo de 60 amperes

Deixe seu comentário e sua avaliação







- Máximo de 512 caracteres. Emojis não são suportados.

Clique para Avaliar


  • Avaliação:
Enviar
Faça seu login e comente.

    TENHA A OPÇÃO DE UTILIZAR ESTE PRODUTO COMO SERVIÇO(OPEX),

     FAZEMOS LOCAÇÃO MENSAL DESTE PRODUTO, CONSULTE-NOS !!!!!!!!